Robinair high tank pressure

Price $21.72. Add To Cart. 17773 Robinair O-Ring For R-134a Quick Seal Fittings (2 Pack) 17773 Robinair O-Ring For R-134a Quick Seal Fittings (2 Pack). Fits the internal face of the quickseal fitting on 134A hoses for recovery equipment, gauge set hoses and tank fill hoses with 1/2" ACME fittings. Price $12.50..

Tanks and Accessories; Skytech Remotes Controls. On/Off Battery Units; Wireless Wall Units; Snap-On Battery Service Parts. Snap-On Alternator/Battery Testers. ... Robinair RA19427 High Pressure Switch. Normally closed switch It opens up at 435 +/- 25 PSI. Related Items: ROBINAIR 529596 ADAPTER,92500 PLUG S/25 X 3/8Robinair Advanced R134A 35 581137 REV D Troubleshooting Display Cause Solution AIR PURGE ERROR DUE TO EXCESSIVE PURGE TIME Possible poor sensor contact with tank Ve...

Did you know?

Robinair34134Z R-134A Recovery Recycling Unit Parts. Oil Inject Bottle 8 oz. For 12 oz. See 115642. 112364 Robinair O-Ring For R-134a Quick Seal Fittings (Each). Fits the internal face of the quickseal fitting on 134A hoses for recovery equipment, gauge set hoses and tank fill hoses with 1/2" ACME fittings. Robinair cannot know, evaluate, and advise you as to all possible hazards. You must verify that conditions and procedures do not jeopardize your personal safety. Explanation of Safety Decals Used on the 34788NI/34788NI-H. Carefully read the instructions. Do not use in open air in case of rain or high hu-midity. Wear gloves. Wear protection goggles.The Robinair AC1234-9 Connected R-1234YF ACS Machine recovers, recycles, evacuates, leak-tests and recharges R-1234yf with improved 98.5% efficiency – unmatched by any competitor. The new design features a large 10" capacitive touch LCD display, and automated features including automatic internal refrigerant refill, oil drain and refrigerant …

The Robinair 34888HD heavy duty machine recovers, recycles, evacuates, ... Compressor: 3/8 hp, pressure protected, oiled, hermetically sealed Dimensions (HxWxD): 49 in x 28 x 39 (124.5 cm x 71 cm x 99 cm) ... Removal External Tank: The ability to switch tanks when performing multiple recoveries on large mobile A/C systemsRobinair Automotive. Technical Support Phone: 800-533-6127 Fax: 866-259-1241 Email: [email protected]. Robinair HVAC/R. Technical Support Phone: 800-327-506017572 — 50 lb. tank with float switch 19776 Optional Accessories Part No. 30Lb (14kg) Recovery Tank 17121 30Lb (14kg) Recovery Tank with 80% capacity sensor 17605 50Lb (23kg) Recovery Tank 17506 50Lb (23kg) Recovery Tank with 80% capacity sensor 17572 50Lb (23kg) High Pressure Recovery Tank with 80% capacity sensor (use with R-410A) RGT50HPAll new proprietary "Oil-less" compressor and 1/2 hp motor. Field serviceable compressor. Multi-refrigerant capable with Self-Clearing feature, which prevents cross-contamination. One 60" hose included. 1/4" MFL fittings. Optional Float Cable provides automatic shut off when tanks are 80% full. Power Source - 115V 60 Hz.

Model 34288 Recovery, Recycling, Recharging Unit Model 34288 Recovery, Recycling, & Recharging Unit SAFETY DEFINITIONS: Follow all WARNING, CAUTION, and NOTE messages in this manual. 19740 Robinair Source Tank Filter For 134A ... RA19427 Robinair High Pressure Switch High Pressure Switch If pressure inside the unit exceeds 435psi, the switch opens, stopping all functions of unit. NOTE: Switch opens at 435psi +/- … ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Robinair high tank pressure. Possible cause: Not clear robinair high tank pressure.

the tank is empty,the machine will not come out of clearing in any mode.i connected a service gauge on the manifold block when entering recovery it pulls down to 20 psi and will go no lower,is the compressor failing,shouldnt it pull to 0 psi.if i close the tank valves with the unit recovering it never hits high pressure.Vacuum Feature: Defaults to 15 mins, programmable up to 99 mins. “Remaining time” is displayed. 22-lb DOT internal tanks. The 34288NI combines simple operation with superior accuracy. It recovers, recycles, evacuates and recharges R-134a mobile A/C systems quickly and accurately.Informs user if tank is full or has high pressure. Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center. Discontinued RA19408 Robinair 115v 100CFM Fan 115v 100CFM Fan Cooling fan positioned to pull air into front of unit across condenser and compressor and discharge it through top of unit.

• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or nationalTo calibrate the scale on Robinair 34288, follow these steps: Turn off the machine and make sure that the scale is empty. Press and hold the "Weight" button for three seconds until "CAL" appears on the display. Place a weight of known mass (such as a 50-pound weight) onto the scale and press the "Weight" button.

developing strategies For Robinair service center use only. Set Date and Time Use the keypad to program the machine for the current date and time. Press "2" for AM and press "7" for PM. System Flush A method of removing oil by forcing liquid refrigerant through an A/C system or components. Tank Fill Transfer refrigerant from the source tank to the internal boo craftmsu vs kansas score May 2, 2012 · the tank is empty,the machine will not come out of clearing in any mode.i connected a service gauge on the manifold block when entering recovery it pulls down to 20 psi and will go no lower,is the compressor failing,shouldnt it pull to 0 psi.if i close the tank valves with the unit recovering it never hits high pressure. Robinair lock out high pressure - iATN. Robinair lock out high pressure. Posted to the Waveform Library on 2/23/2020. Screen shots of what the machine shows when there is high pressure in tank and how to fix it. abir haque I had a similar problem with a Robinair 17800b. The machine got stuck in Clr or (Clearing) while changing from R-12 to R-134a. If the tank (R-12 or R134a) does not have at least 10 pounds of refrigerant in the tank before you change to another refrigerant, the machine will stay in the clearing process.Economy R-134a Recover, Recycle, Recharge Machine, 230V. The 34288NI-230 combines simple operation with superior accuracy. It recovers, recycles, evacuates and recharges R-134A mobile A/C systems quickly and accurately. The product is designed to meet and outperform the most current SAE J-2788 standards for accuracy and efficiency, recovering ... noaa weather binghamtonfjordur mini bossesku stadium renovations The unit includes a 1.5 cfm (42 l/m) Robinair high vacuum pump for fast, thorough evacuation. The compressor pulls the A/C system to 0 psig, then works in series with the vacuum pump to achieve highly efficient recovery and immediate recharge. From https://www.justanswer.com/ythiJustAnswer Customer: MY ROBINAIR MODEL #34788 IS STUCK IN A HIGH PRESSURE RESET MODE AND WILL NOT WORK.JustAnswer Custome... entry level ui designer jobs The fuel system within your vehicle is a complicated collection of many parts, including fuel injection lines, fuel tank, filters and pumps. All of these parts must be working together for the car to run properly. When any one of these part... ku pitt statekevin short nflprimary vs secondary articles Septic tanks are a great way to manage wastewater and sewage in rural areas where there is no access to a municipal sewer system. While septic tanks are an effective solution for wastewater management, they can be expensive to install and m...